Gas / Oil fired boiler IBC GK-7K-Series-Series (76-145 kW)
.
IBC RS-Series (76-145 kW)
Summary of benefits:
  • Three pass design
  • High efficiency
  • Cast iron body
  • Long lifespan
  • Simply handling of control panel
  • Using with oil or gas burner possible
  • Attractive cost price
CE-Zeichen

Characteristic

IBC GK-7K-Series cast iron boilers heat transfer surface area is enlarged with the special wings in chimney ways and combustion area. With special designed flame delay turbulators, maximum heat is transferred to the water in the sections for gaining high efficiency.

Sections are produced with flexible casting technique, EN GJL 200 special cast iron alloy, which gives high resistance against corrosion and thermal expansions.

IBC GK-7K-Series boilers produce more energy with less fuel by its high efficiency and perfect heat isolation.

Burning gases move three times in the boiler with the help of three pass cast iron sections and this minimizes the chimney gas output temperature.

Installation, operation and controls can easily be done with the help of both side opening burner door.

Boilers can easily be delivered and installed to the boiler room as it is delivered completely assembled.

passes-gk-7k



Three draught design forces the flue gas to circulate inside the body of the boiler three times before the chimney exit, transterring all usetull energy to the water inside the sections . The optimized combustion chamber combined with perfect heat insulation provides maximum tuel efficiency.

Technical data sheet  gas or oil fired boiler IBC GK-7K-Series
IBC GK-7K-Series dimensional drawing
Dimensional Drawing

L Boiler length

IBC GK-7K-Series models
/5 /6 /7 /8 /9
Number of sections Pcs. 5 6 7 8 9
Heat output
kW 76 93 110 128 145
kCal/h 65.000 80.000 95.000 110.000 125.000
Heat input
kW 82 101 120 138 157
Operating temperature max °C 90
Range of temperature control
°C 30 - 90
Gas side resistance
mbar 1,40-1,65 1,57-1,82 1,75-2,05 2,00-2,30 2,25-2,55
Maximum operating pressure
max. bar 6
Boiler water content
Litres 55 65 75 85 95
0,055 0,065 0,075 0,085 0,095
Exit flue connection diameter
mm 150 180
Combustion chamber dimensions
mm (ø) 336
mm (L) 550 670 790 910 1.030
Water input - output connection
DN (") G 2"
Gas volume of the boiler
dm³ (lt.) 64,10 78,36 92,62 106,88 121,14
0,064 0,078 0,093 0,107 0,121
Gas volume of the combustion chamber
dm³ (lt.) 45,94 56,16 66,38 76,60 86,82
0,046 0,056 0,066 0,077 0,087
Safety temperature limiter
°C 100
Boiler type
ON / OFF
Fuel type
Gas Natural Gas (I2H)
Liquid F. Liquid Fuel (extra light heat oil)
Exit flue gas temperature
°C (full load) 184-187 179-185 175-182 170-177 169-174
°C (part load) 165-172 164-170 162-168
160-1165 155-160
Exit flue gas mass flow (%13 CO2)
kg/h (full load) 127 156 185 214 243
kg/h (part load) 76 93 111 129 146
Chimney effect
Pa 5
Burner type Short Barrel
Burner flange connection dimension mm 140
Standby loss % 0.32 0.29 0.27 0.23 0.21
kCal/h 2.246 2.506 2.770 2.732 2.835
Boiler length (L) mm 800 922 1.044 1.166 1.288
Dry weight Kg 289 334 381 429 474


Start now and become a heating cost saver with an IBC GK-7K-Series gas / oil fired boiler!