Gas / Oil fired boiler IBC GK-8K-Series (163-355 kW)
.
IBC GK-8K-Series (163-355 kW)
Summary of benefits:
  • Three pass design
  • High efficiency
  • Cast iron body
  • Long lifespan
  • Simply handling of control panel
  • Using with oil or gas burner possible
  • Attractive cost price
CE-Zeichen
Characteristic

IBC GK-8K-Series cast iron boilers heat transfer surface area is enlarged with the special wings in chimney ways and combustion area. With special designed flame delay turbulators , maximum heat is transferred to the water in the sections for gaining high efficiency.

Sections are produced with flexible casting technique, EN GJL 200 special cast iron alloy, which gives high resistance against corrasion and thermal expansions.

IBC GK-8K-Series boilers produce more energy with less fuel by its high efficiency and perfect heat isolation.

Burning gases move three times in the boiler with the help of three pass cast iran sections and this minimizes the chimney gas output temperature.

Installation, operation and controls can easily be done with the help of both side opening burner door.

Boilers can easily be delivered and installed to the boiler room as it is delivered not assembled.

passes-gk-8k

Three draught design forces the flue gas to circulate inside the body of the boiler three times before the chimney exit, transterring all usetull energy to the water inside the sections . The optimized combustion chamber combined with perfect heat insulation provides maximum tuel efficiency.
Technical data sheet  gas or oil fired boiler IBC GK-8K-Series
IBC GK-8K-Series dimensional drawing
Dimensional Drawing

L Boiler length

IBC GK-8K-Series models

/5 /6 /7 /8 /9
/10
/11
Number of sections Pcs. 5 6 7 8 9 10 11
Heat output
kW 163 195 227 259 291 323 355
kCal/h 140.000 167.500 195.000 222.500 250.000 277.500 305.000
Heat input
kW 177 211 246 281 316 351 385
Operating temperature max °C 90
Range of temperature control
°C 30 - 90
Gas side resistance
mbar 1,25-1,60 1,35-1,70
1,55-1,90 1,78-2,20 2,08-2,50 2,37-2,80 2,65-3,10
Maximum operating pressure
max. bar 6
Boiler water content
Litres 77 93 109 125 141 157 173
0,077 0,093 0,109 0,125 0,141 0,157 0,173
Exit flue connection diameter
mm 180
250
Combustion chamber dimensions
mm (W x H) 442 x 391
mm (L) 691 835 979 1.123 1.267 1.411 1.555
Water input - output connection
DN (") DN 80 (3")
Gas volume of the boiler
dm³ (lt.) 142,17 170,43 198,69 226,95 255,21 283,47

311,73

0,142 0,170 0,199 0,277 0,255 0,283 0,312
Gas volume of the combustion chamber
dm³ (lt.) 101,89 122,15 142,40 162,65 182,91 203,16 223,41
0,102 0,122 0,142 0,163 0,183 0,203 0,223
Safety temperature limiter
°C 100
Boiler type
ON / OFF
Fuel type
Gas Natural Gas (I2H)
Liquid F. Liquid Fuel (extra light heat oil)
Exit flue gas temperature
°C (full load) 182-187 178-185 175-180 173-178 173-175 170-173 172-170
°C (part load) 165-172 164-170 162-168
161-165 160-165 158-163 156-161
Exit flue gas mass flow (%13 CO2)
kg/h (full load) 273 326 380 433 487 540 594
kg/h (part load) 164 196 228 260 292 324 356
Chimney effect Pa 5
Burner type

Short Barrel
Burner flange connection dimension mm 185
Standby loss % 0.25 0.24 0.22 0.20 0.19 0.18 0.16
kCal/h 3.780 4.342 4.633 4.806 5.130 5.395 5.270
Boiler length (L) mm 1.070 1.215 1.360 1.505 1.650 1.795 1.940
Dry weight Kg 483 560 636 715 792 869 947


Start now and become a heating cost saver with an IBC GK-8K-Series gas / oil fired boiler!