Gas / Oil fired boiler IBC GK-6K-Series (29-79 kW)
.
IBC GK-6K-Series (29-79 kW)
Summary of benefits:
  • Three pass design
  • High efficiency
  • Cast iron body
  • Long lifespan
  • Simply handling of control panel
  • Using with oil or gas burner possible
  • Attractive cost price
CE-Zeichen
Characteristic

IBC GK-6K-Series cast iron boilers heat transfer surface area is enlarged with the special wings in chimney ways and combustion area. With special designed flame delay turbulators, maximum heat is transferred to the water in the sections for gaining high efficiency.

Sections are produced with flexible casting technique, EN GJL 200 special cast iron alloy, which gives high resistance against corrosion and thermal expansions.

IBC GK-6K-Series boilers produce more energy with less fuel by its high efficiency and perfect heat isolation.

Burning gases move three times in the boiler with the help of three pass cast iron sections and this minimizes the chimney gas output temperature.

Installation, operation and controls can easily be done with the help of both side opening burner door.

Boilers can easily be delivered and installed to the boiler room as it is delivered completely assembled.


passes-gk-6kThree draught design forces the flue gas to circulate inside the body of the boiler three times before the chimney exit, transterring all usetull energy to the water inside the sections . The optimized combustion chamber combined with perfect heat insulation provides maximum tuel efficiency.
Technical data sheet  gas or oil fired boiler IBC GK-6K-Series
IBC GK-6K-Series dimensional drawing
Dimensional Drawing

L Boiler length

IBC GK-6K-Series models
/3 /4 /5 /6 /7 /8
Number of sections Pcs. 3 4 5 6 7 8
Heat output
kW 29,1 39,0 48,8 58,7 68,6 78,5
kCal/h 25.000 33.500 42.000 50.500 59.000 67.500
Heat input
kW 31,6 42,3 53,6 63,8 74,5 85,3
Operating temperature max °C 90
Range of temperature control
°C 30 - 90
Gas side resistance
mbar 0,31-0,46 0,42-0,59 0,61-0,89 0,84-1,25 1,02-1,73 1,19-1,56
Maximum operating pressure
max. bar 4
Boiler water content
Litres 13,74 17,38 21,02 24,66 28,30 31,94
0,0137 0,0174 0,0210 0,0247 0,0283 0,0319
Exit flue connection diameter
mm 130 150
Combustion chamber dimensions
mm (ø) 290
mm (L) 280 380 480 580 680 780
Water input - output connection
DN (") G 1 (¼")
Gas volume of the boiler
dm³ (lt.) 24,20 33,40 42,60 51,80 61,00 70,20
0,024 0,033 0,043 0,052 0,061 0,070
Gas volume of the combustion chamber
dm³ (lt.) 16,94 23,38 29,82 36,26 42,70 49,14
0,017 0,023 0,030 0,036 0,043 0,049
Safety temperature limiter
°C 100
Boiler type
ON / OFF
Fuel type
Gas Natural Gas (I2H)
Liquid F. Liquid Fuel (extra light heat oil)
Exit flue gas temperature
°C (full load) 181-187 175-185 170-182 169-181 167-180 163-176
°C (part load) 160-163 157-160 155-157
152-155 146-150 143-147
Exit flue gas mass flow
kg/h (full load) 49 65 82 98 115 131
kg/h (part load) 29,215 39,148 49,081 59,015 68,948 78,881
Burner type Short Barrel
Burner flange connection dimension mm 106
Standby loss % 0.25 0.23 0.20 0.17 0.15 0.13
kCal/h 678 835 907 926 956 948
Boiler length (L) mm 540 640 740 840 940 1.040
Dry weight Kg 148 175 202 229 256 283


Start now and become a heating cost saver with an IBC GK-6K-Series gas / oil fired boiler!

Request a free, non-binding brochure by post!

 